Building class 4 (GK4)

  • exceptionally fire-retardant

  • Building height: > 7 m to ≤ 13 m

  • Units: ≤ 200 m²

Inner wall

(load-bearing, room-enclosing)

Various wall systems are available for the construction of internal walls requiring high fire resistance, depending on the structural requirements and wall thicknesses.

Desktop view

Abbreviation

10 HT 21-401

10 HT 21-402

10 HT 21-400 LVL

System diagram

8mm

8mm

8mm

Wall thickness [mm]

≥ 200

≥ 140

≥ 140

Substructure [mm]
wooden stand
crossbars


60 x 140
60 x 140


60x80
60x80

Kerto®
45x140 LVL S-beam
45x140 GLVL Q-panel

Sheathing per side [mm]

18 fermacell® + 12 OSB

18 fermacell® + 12 OSB

18 fermacell® + 12 OSB

Permissible voltage σc,0,d,fi [N/mm]*

2.0

1.6

6.0

*σc,0,d,fi already reduced in accordance with MHolzBauRL – Annex 1; A1.2

Mobile view

Abbreviation

10 HT 21-401

System diagram

8mm

Wall thickness [mm]

≥ 200

Substructure [mm]
wooden stand
crossbars


60 x 140
60 x 140

Sheathing per side [mm]

18 fermacell® + 12 OSB

Permissible voltage σc,0,d,fi [N/mm]*

2.0

*σc,0,d,fi already reduced in accordance with MHolzBauRL – Annex 1; A1.2

Abbreviation

10 HT 21-402

System diagram

8mm

Wall thickness [mm]

≥ 140

Substructure [mm]
wooden stand
crossbars


60x80
60x80

Sheathing per side [mm]

18 fermacell® + 12 OSB

Permissible voltage σc,0,d,fi [N/mm]*

1.6

*σc,0,d,fi already reduced in accordance with MHolzBauRL – Annex 1; A1.2

Abbreviation

10 HT 21-400 LVL

System diagram

8mm

Wall thickness [mm]

≥ 140

Substructure [mm]
wooden stand
crossbars

Kerto®
45x140 LVL S-beam
45x140 GLVL Q-panel

Sheathing per side [mm]

18 fermacell® + 12 OSB

Permissible voltage σc,0,d,fi [N/mm]*

6.0

*σc,0,d,fi already reduced in accordance with MHolzBauRL – Annex 1; A1.2

An old example

Internal wall (load-bearing, enclosing the room)

Various wall systems are available for the construction of internal walls that meet fire resistance requirements ranging from standard to highly fire-retardant, depending on the structural requirements and wall thicknesses.

Internal wall (load-bearing, enclosing the room)

Various wall systems are available for the construction of internal walls that meet fire resistance requirements ranging from standard to highly fire-retardant, depending on the structural requirements and wall thicknesses.

Internal wall (load-bearing, enclosing the room)

Various wall systems are available for the construction of internal walls that meet fire resistance requirements ranging from standard to highly fire-retardant, depending on the structural requirements and wall thicknesses.